Skip to content
YTCC

Renewable Energy (Solar / Wind / Hydro)

Monitor your solar, wind and hydro plants in one web interface. YTCC collects data from inverters, turbine controllers and protection devices over Modbus TCP, IEC 60870-5-104, OPC UA and IEC 61850, and shows single-line diagrams, production values and alarms in the browser.

Rows of photovoltaic panels at a solar plant.

Monitor your plants from one screen

Operators of renewable plants watch many inverters, turbines and metering points spread over the site. Active power, daily energy, wind speed and irradiance have to stay current on screen, and an inverter that stops or a turbine that loses communication has to show up at once.

YTCC talks to inverters and field controllers as master over Modbus TCP and to the grid connection point over IEC 60870-5-104; it works as OPC UA client and server, and reads IEC 61850 (MMS) devices by polling. Its MQTT client takes data from field gateways as well. Each driver instance runs in a separate operating system process, and when communication with a device is lost, one alarm is raised per device and its signals go to "no connection" quality.

You draw the plant's single-line diagram in the screen editor with ready-made electrical objects, including solar panel, inverter, wind turbine, hydro turbine, generator and battery storage symbols, and lines are colored by whether they are energized. Internal tags compute total power with an expression and keep counters and running hours. In the historian settings you archive each signal on change or periodically, with a deadband, and set the retention period; the chart object on a screen shows history and the live value together.

You gather alarms by plant or by site in nested alarm groups; group counters show how many alarms are waiting at each plant, and you acknowledge a group at once.

A sample YTCC screen for Renewable Energy (Solar / Wind / Hydro)

A sample YTCC runtime screen for Renewable Energy (Solar / Wind / Hydro): process diagram, status cards, gauges, a trend chart and the alarm list.

A sample screen made for a fictional solar, wind and hydro portfolio: single-line diagram, inverter states, a daily energy chart and the alarm list on one page.

Frequently asked questions

Which protocols does YTCC use to read inverters and turbines?

As master: Modbus TCP and IEC 60870-5-104. As client: OPC UA, IEC 61850 (MMS) reading by polling, and MQTT. YTCC also works as an OPC UA server. Other field protocols are listed on the Platform page.

Can I monitor several plants in the same interface?

Yes. You keep the plants' signals in one project and watch each plant on its own screen and in its own alarm group. User roles and per-page access lists decide who sees which plant's screens.

Are production values archived?

Yes. In the historian settings you archive each signal on change or periodically, with an absolute or percentage deadband, and set the retention period. The historian is kept on PostgreSQL.

YTCC. Your trusted control center for energy and industrial SCADA.

Download YTCC and build your first screen.